Gamma GT 10

Gamma GT 10

(1 customer review)

1,285.00

Overview

Buy Autozyme

Gamma-GT 10 Diagnostic Reagent

(R1 1 x 8 ml: R2 1 x 2 ml) from Accurex. Gamma-GT reagent is used for determination of gamma glutamyl transferase (GGT) in serum and plasma based on the IFCC method. creatinine levels: typical range for serum creatinine is: For adult men, 0.74 to 1.35 mg/dL (65.4 to 119.3 micromoles/L), for adult women, 0.59 to 1.04 mg/dL (52.2 to 91.9 micromoles/L).

Autozyme Gamma-GT estimates GGT activity in just 3 minutes & these reagents are stable till expiry at 2-8°C. AutoZyme Gamma-GT a ready-to-use, two liquid reagent system using single step reconstitution

49 in stock

About

  • AutoZyme Gamma-GT is a reagent set for determination of gamma glutamyl transferase (GGT) in serum and plasma based on the IFCC method.
  • Autozyme Gamma-GT is a ready-to-use, two liquid reagent system using single step reconstitution.
  • Autozyme Gamma-GT estimates GGT activity in just 3 minutes
  • Autozyme Gamma-GT is linear up to 1000 IU.
  • AutoZyme Gamma-GT can be used on any Spectrophotometer, Discrete semi automated and Automated analyzers, Programme can be designed for any specific analyzer upon request.
  • Autozyme Gamma-GT is stable till expiry at 2- 8°C.

Principle

Gamma-glutamyltransferase (GGT) transfers the y-glutamyl group of L–glutamyl-3-carboxy-4-nitroanilide to glycylglycine. The amount of
5-amino-2-nitrobenzoate liberated at 405 nm. is proportional to the activity of GGT in serum/plasma and is measured kinetically

Procedure

Reaction type …………………. Kinetic
Reaction direction …………………. Increasing
Wavelength …………………. 405 nm
Flow Cell temperature …………………. 37°C
Zero setting with ………………….Working solution
Delay time …………………. 60 seconds
No. of readings – 3
Interval …………………. 60 seconds
Sample volume …………………. 0.05 ml (50 ul)
Working solution volume (4 R, : 1 R) ………………….. 1.0 ml (1000 )
Factor …………………. 2201
Linearity …………………. 1000 IUN

Quality Control

To ensure adequate quality control, it is recommended that each batch should include normal and an abnormal commercial reference control the serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect
the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting

Other Details

The reagent kit should be stored at 2- 8°C and is stable till the expiry date indicated on the label.
Reagents are stable till expiry at 2-8°C.
The working solution (4 R,+1 R) is stable for 21 days at 2-8°C.

1 review for Gamma GT 10

  1. Salim Akram

    We are using reagents and instruments. Very good product.

Add a review

Your email address will not be published. Required fields are marked *

Fill Captcha *Time limit exceeded. Please complete the captcha once again.