AT SMART Plus (Semi Automatic Biochemistry Analyzer)

AT SMART Plus (Semi Automatic Biochemistry Analyzer)

150,000.00

Overview

AT Smart Plus – The Next Generation of Smart Biochemistry Analysis

India’s first truly intelligent biochemistry analyzer, AT Smart Plus brings automation, cloud connectivity, and real-time data management to diagnostic labs. Designed and made by Accurex, it delivers smarter testing, easier operation, and greater reliability.

With Automatic Programming, Reagent Inventory Management, Built-in Quality Control, and Multilingual Audio Assist, AT Smart Plus helps reduce manual errors, improve workflow efficiency, and save technician time.

Its 7-inch touchscreen, cloud integration, AI-based algorithms, and voice-guided workflow support make it more than a semi-auto analyzer — it’s a connected, intelligent lab companion.

Key Highlights:

• Cloud-based automatic test programming
• Real-time QC tracking with Levey-Jennings monitoring
• Instant reagent stock alerts & email reporting
• Massive on-device & cloud result storage
• Multilingual Audio Guidance in 12 Indian Languages
• Voice-assisted alerts & workflow support
• Enhanced technician confidence & ease of operation

About

SMART SOLUTIONS FOR MODERN LAB MANAGEMENT

Smart Maintenance

Proactive maintenance tools ensure uninterrupted laboratory operations, minimize downtime, and enhance equipment reliability.

Smart LIS Integration

Seamless Laboratory Information System (LIS) connectivity enables efficient data exchange, faster reporting, and streamlined workflows.

Smart Inventory Management

Automated inventory tracking helps optimize stock levels, reduce wastage, and ensure uninterrupted reagent availability.

KEY BENEFITS

Reduced Errors

Advanced automation enables accurate data collection, streamlined workflows, and reduced manual intervention — minimizing errors and operational waste.

Saves Time

Real-time system monitoring reduces the need for frequent engineer visits, improving efficiency and response time.

Better Patient Experience

An intelligently connected laboratory environment supports faster diagnostics, reliable reporting, and improved patient care.

Instrument Breakdown Management

Continuous real-time monitoring of instrument performance helps identify issues early and prevents unexpected breakdowns.

Online Reaction Curves

Real-time reaction curve monitoring with intelligent flagging enhances diagnostic confidence and improves report accuracy.

Intelligent Software Features

  • User-friendly and intuitive interface
  • 150 direct-access test keys for quick and easy parameter selection
  • Multiple assay modes for flexible testing requirements
  • Efficient workflow management for enhanced productivity

Dry Bath Incubator

  • Equipped with 12 test tube positions
  • Compact and space-saving design
  • Rapid startup time of just 15 minutes
  • Ensures stable and uniform temperature control for reliable incubation results

Specification

AT Smart Plus – India’s First Smart Biochemistry Analyzer

Redefining intelligence in biochemistry testing.
AT Smart Plus combines automation, connectivity, and intelligent data management—built for today’s modern diagnostic labs.

Key Highlights

  • Automatic Programming
    • 1000+ test programming slots
    • Easy parameter downloads from cloud via Wi-Fi
    • Supports up to 10 analytical methods (Endpoint, 2-Point Kinetic, Multi-Point Kinetic)
    • Bi-chromatic and monochromatic readings
    • Intelligent algorithms for automatic method detection (Spline, Linear, etc.)
    • Built-in Peltier temperature control at 25 °C, 30 °C & 37 °C with in-built incubator
  • Advanced Quality Control
    • Supports both Control QC & Lab QC
    • Multi-level QC (up to 30 normal and abnormal values)
    • Levey-Jennings (LJ) plots with Mean, SD, 2SD & 3SD indicators
    • Unlimited QC sample storage
  • Result Management
    • 1,00,000+ results stored internally
    • Real-time reaction curve display for each test
    • Patient details linked with every record
    • Unlimited cloud-based data storage
  • Smart User Interface
    • 7” TFT colour capacitive touch screen
    • HDMI output for external monitor
    • Internal 57 mm thermal printer & USB external printer support
    • 4 USB ports (for mouse, keyboard & printer), Ethernet port & HDMI port
  • Automated Inventory Management
    • Tracks reagent usage automatically
    • Alerts for low stock levels
    • Generates stock statements via email or printer
    • Auto-entry for reagents in test programs downloaded from the cloud.

Safety Information

Precautions & Safety Guidelines

  • The instrument should be operated only by authorized and trained personnel.
  • Unauthorized personnel must not perform servicing, maintenance, or cabinet removal under any circumstances.
  • The power supply should be regulated using a voltage stabilizer or an uninterrupted power supply (UPS). If an inverter is used, ensure that a voltage stabilizer is also connected.
  • It is recommended to use only company-approved reagents for optimum performance and accuracy.
  • The flow cell should be cleaned regularly using the company-recommended flow cell cleaning solution.
  • Users are advised not to use any pointing devices other than those supplied by the company while operating the touchscreen.
  • The instrument should be installed in a clean operating environment and protected from direct sunlight, dust, and excessive humidity.
  • At the end of each working day, ensure that the flow cell is filled with distilled water to maintain proper functioning and prevent clogging.
  • During transportation or extended shutdown periods, proper shutdown and protective procedures should be followed as recommended by the company.
  • Regular preventive maintenance should be carried out to ensure reliable performance and extended instrument life.
  • Ensure adequate ventilation around the instrument for safe and efficient operation.
  • Avoid sudden power interruptions or improper shutdown procedures to prevent data loss and equipment damage.

Direction for Use

Installation & Operating Guidelines

  • Ensure that the power source is properly grounded and that the voltage between Line and Ground remains within 2V AC to 5V AC for safe and stable operation.
  • Place the instrument on a firm, vibration-free table in a clean environment with adequate ventilation space around the unit.
  • Switch on the instrument and allow it to initiate its internal diagnostic routines, which verify the proper functioning of critical system components.
  • Allow the instrument to stabilize for approximately 10 minutes before beginning operation.
  • During the stabilization period, clean the flow cell thoroughly by rinsing it at least twice with the recommended cleaning solution followed by distilled water.
  • Before shutting down the instrument, ensure that the flow cell is properly cleaned using the recommended flow cell cleaning solution and rinsed thoroughly with distilled water.
  • For overnight shutdowns, ensure that the flow cell remains filled with distilled water to prevent clogging and maintain optimal performance.
  • After use, always protect the instrument by covering it with the provided dust cover to minimize dust accumulation and extend equipment life.
  • Avoid exposure to direct sunlight, excessive humidity, or corrosive environments to maintain consistent instrument performance.
  • Regular cleaning and preventive maintenance are recommended to ensure long-term reliability and accuracy.

Other Info

General Information

During the installation and setup of the instrument, all safety instructions and general precautions described in the following sections must be carefully observed to ensure safe, reliable, and efficient operation.

Power Supply Requirements

  • The power source must be properly grounded and connected through a servo stabilizer or regulated power backup system (UPS) to ensure stable operation.
  • Use only power cords that are CE, CSA, and UL certified for enhanced electrical safety and compliance with international standards.
  • Operating Voltage: 115 – 230 Volts ±10%, 50 – 60 Hz
  • Grounding: Ensure that the electrical power source is correctly grounded before operating the instrument to prevent electrical hazards and equipment damage.
  • Avoid sharing the power outlet with heavy electrical equipment that may cause voltage fluctuations or electrical interference.
  • It is recommended to use a dedicated power line for optimal instrument performance and protection.