Magnesium 50

Magnesium 50

(1 customer review)

1,268.00

Overview

Buy

Infinite Liquid Magnesium 50 Diagnostic Reagent

(Pack size: 2X 25ml) from Accurex. Liquid Magnesium reagent kit is used for determination of magnesium concentration in human serum and plasma based on colorimetric blue method.

Liquid Magnesium is a ready-to-use, single liquid reagent system & Magnesium can be determined in just 5 minutes at 37°C. The Magnesium Reagent kit should be stored at 2- 8°C & is stable till the expiry date indicated.

5 in stock

About

  • Infinite Liquid Magnesium is a reagent set for determination of magnesium concentration in human serum and plasma based on colorimetric blue method.
  • Infinite Liquid Magnesium is a ready-to-use, single liquid reagent system.
  • Magnesium can be determined in just 5 minutes at 37°C.
  • Infinite Liquid Magnesium is linear upto 5 mg dl.
  • Infinite Liquid Magnesium can be used on any Spectrophotometer, Discrete semi automated and Automated analyzers. Programmed can be designed for any specific analyzer upon request.
  • There is no significant interference in samples containing upto 50 mg/dl of Bilirubin and upto 39 mg/dl of Ascorbic Acid.

Principle

Magnesium ions react with xylidyl blue in an alkaline medium to form purple coloured complex. The intensity of the purple color is directly proportional to the concentration of magnesium in the specimen.

Procedure

Reaction type ……………… End-Point
Reaction time …………. 10 mins. at 37°C/20 mins. at R.T. (25-30°C)
Wavelength ………………….. 510 nm. (500 – 530 nm.)
Zero setting with ………………… Reagent Blank
Blank absorbance limit ………… < 0.300 Abs.
Sample volume …………………………… 0.01 ml (10 jul)
Reagent volume …………………… 1.0 ml
Standard concentration ……………. 200 mg%
Linearity ………………… 800 mg/dl

Quality Control

To ensure adequate quality control, it is recommended that each batch should include normal and an abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting.

Other Details

  • The reagent and standard are ready-to-Use and are stable till expiry whenstored at 2- 8°C.
  • Contamination of the reagent should be strictly avoided.
    The kit should be stored at 2- 8°C and is stable till the expiry date indicated

 

1 review for Magnesium 50

  1. Mrunal Thakur

    We are using the accurex products since 15 years. Its to give accurate result.

Add a review

Your email address will not be published. Required fields are marked *

Fill Captcha *Time limit exceeded. Please complete the captcha once again.

×

Hello!

Click below to chat with us on WhatsApp

×