Infinite Liquid GPT (ALT) 100 Diagnostic Reagent

(R1 2 X 40ml: R2: 2 X 10ml) from Accurex. Glutamate Pyruvate Transaminase reagent is used for determination of True Glucose, based on enzymatic method using Glucose, oxidase & Peroxidase. α-ketoglutarate reacts with L-alanine in presence of GPT (ALT) to form

pyruvate and Glutamate

. Accurex Biomedical is the first biochemical reagents manufacturing company in India.

5 in stock

About

  • Ready-to-use, 2 liquid reagent system
  • High stability
  • Need based reconstitution possible
  • Freedom from worry of reagent expiry
  • High liquid stability
  • High linearity
    Pack Size : R1: 2 x 40 ml R2: 2x10ml

Principle

α-ketoglutarate reacts with L-alanine in presence of GPT (ALT) to form pyruvate and Glutamate. The increase in pyruvate is determined in an indicator reaction catalyzed by lactate dehydrogenase. The conversion of NADH to NAD at 340 nm. is proportional to the activity of GPT (ALT) in Serum Plasma and is determined kinetically as rate of decrease in absorbance.

 

Procedure

Reaction type …………..UV – Kinetic
Reaction direction ………. Decreasing
Wavelength ……………… 340 nm.
Flow Cell temperature….. 37°C
Zero setting with …….. Distilled water
Delay time ……………….. 60 seconds
No. of readings …..4
Interval…… 30 seconds
Blank absorbance limit ……………. 20.900 Abs.
Sample volume ……… 0.05 ml (50 ml)
Working solution volume (4 R, : 1 R.) ……….. 1.0 ml (1000 ul)
Factor ……… 3339
Linearity …………….. 600 IU/I

Quality Control

To ensure adequate quality control, it is recommended that each batch should include normal and an abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting.

Other Details

The reagent kit should be stored at 2 – 8°C and is stable till the expiry date indicated on the label.
R, and P, reagents are stable till expiry at 2- 8°C.
The working solution (4 R, +1 R,) is stable for 30 days at 2- 8°C.

 