AutoPure LDL Cholesterol 240

AutoPure LDL Cholesterol 240

(6 customer reviews)

61,068.00

Overview

Buy

AutoPure LDL Cholesterol 240

(R1 4 X 45ml: R2 4 X 15 ml) from Accurex. LDL Cholesterol 240 Reagent is used for direct quantitative determination of Low Density Lipoprotein Cholesterol (LDL-C) in human serum and plasma on automated clinical chemistry analyzers.

AutoPure LDL Cholesterol 240 Reagent is a ready-to-use, two liquid reagent system & With AutoPure HDL-C the assay is linear upto 450 mg/dl (11.637 mmol/l). Cholesterol 240 can be used on various automated analyzers. LDL Cholesterol 240 Reagent kit should be stored at 2-8°C & is stable till the expiry date.

50 in stock

About

  • AutoPure LDL-C is a reagent kit for direct quantitative determination of Low Density Lipoprotein Cholesterol (LDL-C) in human serum and plasma on automated clinical chemistry analyzers.
  • AutoPure LDL-Cis ready-to-use, two liquid reagent system.
  • With AutoPure LDL-C, the assay is linear upto 450 mg/dl (11.637 mmol/l).

Principle

AutoPure LDL-Cholesterol assay is a homogenous method for directly measuring LDL-C levels in the serum or plasma without the need for any off-line pretreatment or centrifugation steps. In the first reaction, non LDL unesterified cholesterol is subject to an enzyme reaction and the peroxide generated is consumed by peroxidase in the presence of 4 – AAP to yield a colourless product. The second reagent consists of a detergent capable of solubilizing LDL specifically. Cholesterol esterase and chromogenic coupler react with this solubilized LDL-C to develop colour. The intensity of the colour formed is directly proportional to the concentration of the LDL-C in the specimen and is measured photometrically.
Collect sample using standard sampling tube. Serum, EDTA treated or sodium heparinized plasma are the recommended specimens. Patients are not required to fast prior to blood collection. Serum or plasma should not remain at 150-30°C for more than 14 hours. If assay is not completed within 14 hours, serum or plasma may be stored at 20- 8°C upto 1 week. If the specimens need to be stored for more than a week, they may be preserved at less than -70°C upto 3 months.

Procedure

AutoPure LDL-C can be used on various automated analyzers.

Quality Control

Each batch of AutoPure LDL-C is assayed with multiple quality control sera prior to release. To ensure adequate quality control, it is recommended that the laboratory should use a normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both the reagent and instrument functions together. If the control values fall outside the specified limits, each of the below criteria should be cross-checked and corrected:


• Proper instrument function – wavelength setting, light source and temperature control.
• Cleanliness of probes and cuvettes.
• Bacterial contamination of wash water used by the instrument.
• Expiry date of the reagent kit.

Other Details

  • The kit should be stored at 2-8°C and is stable till the expiry date indicated on the label.
  • The reagent and standard are ready-to-use and are stable till expiry, when stored at 2- 8°C. DO NOT FREEZE THE REAGENT.

6 reviews for AutoPure LDL Cholesterol 240

  1. Akhil Yadav

    Gives perfiect result for direct quantitative determination of Low Density Lipoprotein Cholesterol (LDL-C)

  2. Sushant Lade

    I am using Accurex products 3 years I am satisfied with reagent good service

  3. Sangeeta Sharma

    I am using Accurex product AutoPure LDL Cholesterol 7 years I am satisfied with reagent good service

  4. Tahir Ahmed

    We are using Accurex products from many year’s and getting good results and prompt service as well

  5. Vipin Nair

    I am using accurex reagents last 6–8 months this reagents results are very good quality

  6. Shrinivas Reddy

    I am fully satisfied with product quality

Add a review

Your email address will not be published. Required fields are marked *