AutoPure CK-NAC 25

AutoPure CK-NAC 25

(2 customer reviews)

4,500.00

Overview

Buy

AutoPure CK-NAC 25 Diagnostic Reagent

(R1 1 X 20ml: R2 1 X 5ml) from Accurex. CK-NAC 25 Reagent is used for direct quantitative determination of CK-NAC in human serum and plasma on automated clinical chemistry analyzers.

CK-NAC is a ready-to-use, two liquid reagent system & the assay is linear upto 2000 IU/(33.4 kati). The CK NAC Reagent kit should be stored at 2-8°C & is stable till the expiry date.

5 in stock

About

  • AutoPure CK-NAC is reagent kit for direct quantitative determination of CK-NAC in human serum and plasma on automated clinical chemistry analyzers.
  • AutoPure CK-NAC is a ready-to-use, two liquid reagent system.
  • With AutoPure CK-NAC, the assay is linear upto 2000 IU/ (33.4 kati).

Principle

Glucose oxidase, oxidizes glucose to gluconic acid in the presence of
atmospheric oxygen.

In presence of peroxidase, hydrogen peroxide oxidatively couples.
with 4-aminoantipyrine and phenol to produce red quinoneimine dye.
The intensity of the red color formed is directly proportional to the
concentration of glucose in the specimen and is measured
photometrically.

Quality Control

Each batch of AutoPure Calcium Arsenazo III is assayed with at least six quality control sera-Precinorm**, Precipath**, Bio Rad I***, Bio Rad II***, Accutrol Normal and Accutrol Abnormal prior to release-, To ensure adequate quality control, it is recommended that the laboratory should use a normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both the reagent and instrument functions together. If the control values fall outside the specified limits, each of the below criteria should be cross-checked and corrected:
• Proper instrument function – wavelength setting, light source and temperature control.
• Cleanliness of probes and cuvettes.
• Bacterial contamination of wash water used by the instrument.
A comparison of the calcium determination using AutoPure Calcium Arsenazo III and AutoZyme Calcium Arsenazo III reagent gave the following correlation (mg/dl): Linear Regression y=0.949x+0.574 r=0.941 Sy.x=0.33

Other Details

  • The kit should be stored at 2-8°C and is stable till the expiry date indicated on the label.
  • The reagent and standard are ready-to-use and are stable till expiry, when stored at 2- 8°C. DO NOT FREEZE THE REAGENT.

2 reviews for AutoPure CK-NAC 25

  1. John K

    I like the product . Good product in cheap price . Quality is good

  2. Deepak

    The reagent’s performance on our analyzers has consistently met our expectations, delivering accurate measurements with minimal variation.

Add a review

Your email address will not be published. Required fields are marked *

Fill Captcha *Time limit exceeded. Please complete the captcha once again.

×

Hello!

Click below to chat with us on WhatsApp

×