AutoPure Chloride 80

AutoPure Chloride 80

(3 customer reviews)

2,403.00

Overview

Buy

AutoPure Chloride 80 Diagnostic Reagent

(Pack Size: 4 X 20ml) from Accurex. Chloride 80 Reagent is used for direct for direct quantitative determination of Chloride in human serum & plasma on automated clinical chemistry analyzers.

AutoPure Chloride is a ready-to-use, single liquid reagent system. The Chloride Reagent kit should be stored at 2-8°C and is stable till the expiry date. Chloride in Blood are one of the electrolytes. Chloride blood tests check to make sure you have appropriate levels (Chloride High & Low) of chloride in your blood to be healthy.

50 in stock

About

  • AutoPure Chloride is a reagent kit for direct quantitative determination of Chloride in human serum and plasma on automated clinical chemistry analyzers.
  • AutoPure Chloride is a ready-to-use, single liquid reagent system.
  • With AutoPure Chloride, the assay is linear upto 130 mmol/l (458.9 mg/dl).

Principle

Fully automated systems automatically calculate the Chloride concentration of each sample. Results in mg/dl = Results in mmol/l x 3.53 Chloride ions react with mercuric thiocyanate to form undissociated mercuric chloride and free thiocyanate ions.

 

Procedure

AutoPure Chloride can be used on various automated analyzers. The procedure described below is for Sphera auto-analyzer.
493 Sec. 37°C 6 Measurement at 505 nm Expected range varies from population to population. It is therefore recommended that each laboratory should establish its own normal range. For diagnostic purposes, the Chloride results should always be assessed in conjunction with the patient’s medical history, clinical examinations and other findings

Quality Control

Each batch of AutoPure Chloride 80 is assayed with at least six quality control sera-Precinorm**, Precipath**, Bio Rad I***, Bio Rad II***, Accutrol Normal and Accutrol Abnormal prior to release-, To ensure adequate quality control, it is recommended that the laboratory should use a normal and abnormal commercial reference control serum. It should be realized that the use of quality control material checks both the reagent and instrument functions together. If the control values fall outside the specified limits, each of the below criteria should be cross-checked and corrected:


• Proper instrument function – wavelength setting, light source and temperature control.
• Cleanliness of probes and cuvettes.
• Bacterial contamination of wash water used by the instrument.
A comparison of the calcium determination using AutoPure Calcium Arsenazo III and AutoZyme Calcium Arsenazo III reagent gave the following correlation (mg/dl): Linear Regression y=0.949x+0.574 r=0.941 Sy.x=0.33

Other Details

  • The kit should be stored at 2-8°C and is stable till the expiry date indicated on the label.
  • The reagent and standard are ready-to-use and are stable til expiry, when stored at 2- 8°C. DO NOT FREEZE THE REAGENT.

3 reviews for AutoPure Chloride 80

  1. Avi K

    For adequate quality control, it is recommended

  2. Manav

    One of the notable features of the Chloride 80 Reagent is its compatibility with automated clinical chemistry analyzers.

  3. Tanmay

    I recommend the Chloride 80 Reagent to other clinical laboratories seeking a dependable solution for the direct quantitative determination of Chloride levels

Add a review

Your email address will not be published. Required fields are marked *

Fill Captcha *Time limit exceeded. Please complete the captcha once again.