Hormones & Cardiology
AccuDx CQ – PCT (25 Test)
₹30,529.00Overview
Buy AccuDx CQ PCT Fast Test Kit (Immunofluorescence Assay) used for determination of
Procalcitonin (PCT)
in serum, plasma or whole blood. The pct blood test is used as an aid in the assessment and evaluation of patients Suspected of bacterial infection, trauma or shock. PCT is a
peptide precursor
of the hormone calcitonin, the latter being involved with calcium homeostasis.
It is composed of 116 amino acks and is produced by parafollicular cells (C cells) of the thyroid and by the neuroendocrine calls of the lung and the intestine. Procalcitonin test measures how much procalcitonin is in your blood. The procalcitonin normal range in adults is less than 0.1 ng/mL.
AccuDx CQ D-Dimer (25 Test)
₹18,500.00Overview
Buy AccuDx
D-Dimer Fast Test Kit
(Immunofluorescence Assay) used for determination of D-Dimer in plasma or whole blood. The d dimer test is used as an aid in assessment & evaluation of patients suspected of deep vein thrombosis or pulmonary embolism. d dimer blood test.
D Dimer normal range is considered less than 0.50. D-Dimer is a marker of endogenous fibrinolysis and should therefore be detectable in patients with deep-vein thrombosis.
AccuDx CQ HsCRP (25 Test)
₹10,181.00Overview
Buy ACCUDx CQ hs CRP+CRP Kit (Immunofluorescence Assay) used for the determination of
C-reactive protein (CP)
in serum, plasma or whole blood. Measurement of hscrp levels are useful for the detection and evaluation of infection, tissue injury and inflammatory disorders.
Measurement of hscrp meaning High-sensitivity C-reactive protein (hsCRP), when used in conjunction with traditional clinical laboratory evaluation of acute coronary syndromes (ACS), may be useful as an independent marker of prognosis for recurrent events in patients with stable coronary disease or ACS. High level of hs CRP in the blood has results in increased risk of heart attacks.
AccuDx CQ IL-6 (25 Test)
₹23,000.00Overview
Buy IL-6 Fast Test Kit (Immunofluorescence Assay) used for determination of
Interleukin 6 (IL-6)
in human serum, plasma, whole blood and peripheral blood samples. IL-6 is an early maker in acute inflammation and this test can be used as an aid in the inflammatory diseases.
Interleukin 6 is a cytokine that functions in inflammation and maturation of B calls. Interleukin 6 functions: primely produced at sites of acute and chronic inflammation, where it is secreted into the serum and induces a transcriptional inflammatory response.
AccuDx CQ NT-Pro BNP (25 Test)
₹34,000.00Overview
Buy AccuDX CQ NT-pro BNP Fast Test Kit (Immunofluorescence Assay) used for determination of
N-terminal B-type natriuretic peptide precursor
(NT-pro BNP) in serum, plasma or whole blood. NT pro BNP test is used as an aid in the clinical diagnosis, prognosis and evaluation of Heart Failure (HF).
NT pro BNP means N-terminal B-type natriuretic peptide precursor & the normal range for NT-proBNP is lower than 125 pg/mL for adults younger than 75 years and lower than 450 pg/mL for adults 75 years or older. NT-proBNP is a risk assessment indicator for Acute Coronary Syndrome.
AccuDx CQ Quantitative Analyzer
₹150,000.00Overview
AccuDx CQ is a Near Patient Critical Care Quantitative Analyzer.
Best Criticare Analyzer
in the
Point of Care (POC)
Range from Accurex which gives Instant Quantitative result for Troponin I, Hs-CRP, D-Dimer & PCT.
Key Points: Portable Design, Light in weight, Small in size, Easy to Use, One step test, automatic print, quantitative result, Multiple Test Items, Cardiac and Inflammatory, Reliable Performance, CV ≤ 1%, R ≥ 0.990, LIS and HIS connectivity. AccuDx CQ uses a semiconductor diode laser as the excitation light source for illuminating the test cartridge membrane thereby triggering fluorescence from the fluorochrome molecules present on the membrane.
AccuDx CQ T3 (25 Test)
₹6,250.00Overview
Buy AccuDx CQ
T3 (Triiodothyronine) Fast Test Kit
(Immunofluorescence Assay) used for determination of T3 in serum & plasma. Accurex Triiodothyronine test can be used in the monitoring of hyperthyroidism and hypothyroidism, and also used as an aid in the functional diagnosis of thyroideus.
Triiodothyronine test performed as part of an evaluation of thyroid function. The thyroid gland exerts powerful & essential regulatory influences on growth, differentiation, cellar metabolism & general hormonal balance, as well as on the maintenance of metabolic activity & the development of the skeletal and organ system.
AccuDx CQ T4 (25 Test)
₹6,250.00Overview
Buy AccuDx CQ
T4 (Thyroxine) Fast Test Kit
(Immunofluorescence Assay)used for determination of T4 in serum and plasma.
Accurex Thyroxine T4 test can be used in the monitoring of hyperthyroid- ism and hypothyroidism, and also used as an aid in the functional diagnosis of thyroideus. Only less than 1% of thyroxine remains unbound as free T4 in blood. Thyroxine is the most commonly measured substance in the assessment of thyroid function. Most Thyroxine secreted into the bloodstream is bound to a transport protein – thyroxine binding globulin (TBG) & to albumin and pre-albumin.
AccuDx CQ Triple Marker – CKMB/Myo/TnI (25 Test)
₹30,000.00Overview
Buy AccuDx Triple Marker
CK-MB/cTnI/yo Fast Test Kit
(Immunofluorescence Assay) used for determination of CK-MB/cTnl/Myoin serum, plasma or whole blood.
Triple marker test is used as an aid in the clinical diagnosis, prognosis and evaluation of myocardial injury such as Acute Myocardial Infarction (AMI), Unstable Angina, Acute Myocarditis and Acute Coronary Syndrome. Kit contains: ACCUDx CQ CK-MB/CTnI/Myo test card in a sealed pouch with desiccant 25, Disposable pipet, Whole blood buffer, SD/RFID card, User manual, Whole blood buffer composition: Phosphate buffered saline, proteins, detergent, preservative, stabilizer.
AccuDx CQ TSH (25 Test)
₹6,750.00Overview
Buy
TSH Fast Test Kit
(Immunofluorescence Assay) used for determination of thyroid-stimulating hormone (TSH) in serum and plasma. TSH test is used in the screening, clinical diagnosis, prognosis and therapeutic effect evaluation of thyroid diseases.
TSH means thyroid stimulating hormone. TSH normal range are 0.5 to 5.0 mIU/L. TSH blood test – The fluctuation of TSH is faster and more significant than thyroid hormones when thyroid function was changed, it is a sensitive biomarker of hypothalamic-pituitary-thyroid function.
Lipid Diag Strips (25 Strips)
₹8,000.00Overview
Buy Blood Lipid Test Strip from Accurex. These
Lipid Test Strips
are for the quantitative determination of total cholesterol, HDL (high density lipoprotein) cholesterol & triglycerides in venous whole blood & capillary whole blood from the fingertip and are intended for multiple patient use in professional healthcare settings.
When blood is applied to a test strip – the blood reacts to produce color that is read by the blood lipid analyzer using reflectance photometry. The amount of color produced is proportional to the concentration.
Lipid Meter
₹25,000.00Overview
Buy The
Blood Lipid Analysis System
(Pack of 25 strips) from Accurex. The Blood Lipid Analysis System (lipid profile test) is used for quantitative determination of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL), Triglycerides (TG), and the calculated ratio of TC/HDL & Low Density Lipoprotein Cholesterol (LDL) in capillary blood, venous whole blood, plasma & serum. The Blood Lipid meter can store up to 500 results and records. The meter can be operated by charging battery.
- 1
- 2
