Microprotein 100

Microprotein 100

(1 customer review)

819.00

Overview

Buy

Infinite Liquid Microprotein 100 Diagnostic Reagent

(Pack size: 2X 25ml) from Accurex. Liquid Magnesium reagent kit is used for determination of protein in human urine & CSF based on Pyrogallol red method.

Microprotein 100 is linear upto 300 mg/dL & Microprotein assay can be performed in 5 minutes at 37° C. Microprotein reagent kit should be stored at 2° to 8° C & is stable till the expiry date.

50 in stock

About

  • Infinite Microprotein is a reagent set for quantitative determination of protein in human urine & CSF based on Pyrogallol red method.
  • Infinite Microprotein is a ready-to-use, single liquid reagent system.
  • Infinite Microprotein, is linear upto 300 mg/dL
  • Infinite Microprotein assay can be performed in 5 minutes at 37° C.


Method – Pyrogallol Red
Pack Size : 4 * 25 ml

Principle

Pyrogallol red is combined with molybdenum acid at a low pH. When the complex is combined with protein, a blue-purple color is formed. The intensity of the color developed is directly proportional to the protein concentration in the sample and is measured at 600 nm.

Procedure

Reaction type………….………………End-Point
Wavelength………….…….600 nm(578/630 nm)
Flow Cell temperature…………….…………37° C
Zero setting with………….…………….Reagent
Sample volume……….…………..…….……20 µl
Reagent volume…………..………………..1000 µl
Standard Concentration….………….100 mg/dL
Linearity……….…….……………………300 mg/dL

Quality Control

To ensure adequate quality control, it is recommended that each batch should include normal and an abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of pipetting.

Other Details

– The reagent is ready-to-use.
– The reagent kit should be stored at 2° – 8° C and is stable till the expiry date indicated on the label.
– Keep the Reagent away from direct light sources. Do not freeze the reagent.
– Contamination of the reagent should be strictly avoided.

1 review for Microprotein 100

  1. Hemant Patil

    I m using Accurex Reagents and semi auto with good service

Add a review

Your email address will not be published. Required fields are marked *

Fill Captcha *Time limit exceeded. Please complete the captcha once again.