ADA 60 – Infinite

ADA 60 – Infinite

(5 customer reviews)

20,423.00

Overview

Buy

Infinite ADA 60 Diagnostic Reagent

(R1 1 X 20ml: R2 1 X 10 ml) from Accurex. Infinite ADA reagent is used for direct quantitative determination of Adenosine deaminase (ADA) activity in human serum, plasma and other body fluids.

The Reagent is a ready-to-use two liquid reagent system & can be performed in 11 minutes at 37° C. ADA is also know as Adenosine Deaminase which eliminates a molecule called deoxyadenosine, which is generated when DNA is broken down.

5 in stock

About

  • Infinite ADA is a reagent set for direct quantitative determination of Adenosine deaminase (ADA) activity in human serum, plasma and other body fluids.
  • Infinite ADA is a ready-to-use, two liquid reagent system.
  • With Infinite ADA, the assay is linear upto 200 U/L.
  • Infinite ADA assay can be performed in 11 minutes at 37° C.

Principle

ADA catalyzes deamination of adenosine to inosine which is then converted to hypoxanthine by purine nucleoside phosphorylase (PNP). Hypoxanthine is then converted to uric acid and hydrogen peroxide (H2O2) by xanthine oxidase (XOD). H2O2 is further reacted with N-Ethyl-N-(2-hydroxy-3- sulfopropyl)-3-methylaniline (EHSPT) and 4-aminoantipyrine (4 AAP) in the presence of peroxidase (POD) to generate quinone dye.

Procedure

• Reaction type…………………………………….Kinetic
• Reaction direction……………………………Increasing
• Wavelength………………………………………546 nm
• Flow Cell temperature……………………………..37° C
• Zero setting with……………………….Distilled water
• Delay time…………………………………300 seconds
• No. of readings………………………………………….4
• Interval………………………………………60 seconds
• Sample volume……………………………………..10 μl
• R 1 volume…………………………………………..360 μl
• R 2 volume…………………………………………180 μl
• Factor…………………………………………………1743
• Linearity……………………………………………200 U/L

Quality Control

To ensure adequate quality control, it is recommended that
each laboratory should use a normal and an abnormal
commercial reference control material. It should be realized
that the use of quality control material checks both reagent
and instrument functions together. Factors which might affect
the performance of this test include instrument function,
temperature control, cleanliness of glasswares and accuracy
of pipetting.

Other Details

The reagents R1 & R2 are ready-to-use.
The reagent kit should be stored at 2° – 8° C and is stable till
the expiry date indicated on the label.
Reagent R1 is light-sensitive & to be stored in dark.
Contamination of the reagents should be strictly avoided.

 

5 reviews for ADA 60 – Infinite

  1. Shubham

    Infinite ADA is also available in mono pack.

  2. Shrutik Rajan

    Accurex is a quality based reagents manufacturing company .We are satisfied with your products

  3. Amrut Singh

    reagent and rapid cards quality are superb.

  4. Sagar Ram

    I am using Accurex produts 3 years I am satisfied with reagent good service

  5. Sonali Gadkar

    Satisfied with reagent good service

Add a review

Your email address will not be published. Required fields are marked *

Fill Captcha *Time limit exceeded. Please complete the captcha once again.

×

Hello!

Click below to chat with us on WhatsApp

×