Triglycerides 600 – Infinite

Triglycerides 600 – Infinite

(5 customer reviews)

13,613.00

Overview

Buy

Infinite Liquid Triglyceride 600 Diagnostic Reagent

from Accurex. Liquid Triglycerides reagent kit is used for determination of triglycerides based on enzymatic methods using Lipoprotein lipase, Glycerol kinase, Glycerol phosphate oxidase and Peroxidase.

Triglyceride Reagent is a ready to use reagent & can be determined in just 10 minutes at 37°C or 20 minutes at Room Temperature (25°C – 30°C). The Triglyceride 600 kit should be stored at 2- 8°C and is stable till the expiry date indicated on the label. Triglycerides normal range is Less than 150 milligrams per deciliter (mg/dL) or less than 1.7 millimoles per liter (mmol/L).

50 in stock

About

  • Infinite Liquid Triglycerides 600 is a reagent set for determination of triglycerides, based on enzymatic methods using Lipoprotein lipase, Glycerol kinase, Glycerol phosphate oxidase and Peroxidase.
  • Infinite Liquid Triglycerides 600 is a ready to use reagent.
  • Triglycerides 600 can be determined in just 10 minutes at 37°C or 20 minutes at R.T. (25°C – 30°C).
  • Infinite Liquid Triglycerides 600 is linear upto 800 mg%.
  • Infinite Liquid Triglycerides 600 can be used on any Colorimeter, Spectrophotometer, Discrete semi automated and Automated analyzer. Programme can be designed for any specific analyzer upon request.
  • The influence of lipids, haemolysis and bilirubin (upto 8 mg%) is negligible.

Principle

Glycerol released from hydrolysis of triglycerides by lipoprotein lipase is converted by glycerol kinase into glycerol-3- phosphate which is oxidized by glycerol phosphate oxidase to dihydroxyacetone phosphate and hydrogen peroxide. In presence of peroxidase, hydrogen peroxide oxidizes phenolic chromogen to a red coloured compound.

Procedure

Reaction type ………… ………. End-Point
Reaction time …. 10 mins. at 37°C/20 mins. at R.T. (25-30°C)
Wavelength ……….. ………… 510 nm. (500 – 530 nm.)
Zero setting with ……….. ………… Reagent Blank
Blank absorbance limit … ……… < 0.300 Abs.
Sample volume …………………………… 0.01 ml (10 jul)
Reagent volume ……….. …………. 1.0 ml
Standard concentration .. …………… 200 mg%
Linearity ……………. ….. 800 mg/dl

Quality Control

To ensure adequate quality control, it is recommended that
each laboratory should use a normal and an abnormal
commercial reference control material. It should be realized
that the use of quality control material checks both reagent
and instrument functions together. Factors which might affect
the performance of this test include instrument function,
temperature control, cleanliness of glasswares and accuracy
of pipetting.

Other Details

The kit should be stored at 2-8°C and is stable till the expiry date indicated on the label.
The reagent and standard are ready-to-use and are stable til expiry, when stored at 2- 8°C. DO NOT FREEZE THE REAGENT.
The reagent should be stored only in the amber bottle provided to protect it from direct light. Before using, swirl in the reagent gently. DO NOT SHAKE VIGOROUSLY.
Over time, the reagent may develop a light pink colour. This is expected and does not affect the reagent performance. Discard the reagent if the absorbance of the same exceeds 0.300 O.D. against distilled water at 510 nm.
Contamination of the reagent should be strictly avoided. Should the
reagents develop turbidity and discard the reagent.

5 reviews for Triglycerides 600 – Infinite

  1. Rameshan N K

    company product is very good

  2. Akash Sharma

    Quality reagent

  3. Himanshu Khatri

    Affordable and best quality reagents

  4. Manisha Zagade

    I have use this product is really nice

  5. Yash Ahire

    . It is good and satisfied in your product

Add a review

Your email address will not be published. Required fields are marked *

Fill Captcha *Time limit exceeded. Please complete the captcha once again.