About
•SMART MAINTENANCE
•SMART LIS
•SMART INVENTORY MANAGEMENT
REDUCED ERRORS:
IT allows for the accurate collection of data, automated workflows &
minimized waste.
SAVES TIME:
Patient monitoring can be done in real-time, saves engineers visiting time.
BETTER PATIENT EXPERIENCE:
A connected laboratory system creates an environment that meets each patient’s needs.
INSTRUMENT BREAKDOWN MANAGEMENT:
Real-time data helps to monitor instrument performance.
ONLINE REACTION CURVES:
• Real time reaction curve with special
• Flagging gives confidence in patient reports.
INTELLECTUAL SOFTWARE:
• User friendly Device.
• 150 Direct access test keys gives freedom
to select parameters easily.
• Availability of different assay modes.
DRY BATH INCUBATOR:
• Dry bath incubator with 12 test tube positions
• Mini size with 15 minutes start up time
Specification
FEATURES:
•Remote access & monitoring via Internet
•150 test parameters
•Built-in thermal printer to print results, enzymatic curves and standard calibration curves
•Large graphic display with real time graph display for enzymatic reaction
•Touch screen interface with dynamic test access key
SPECIFICATIONS:
Methodology-
• Absorbance
• Endpoint with standard, factor, sample blank & diffrential
• Two-point (fixed time) and multi point kinetics
• Multi standard calibration
• Mono or bi-chromatic reading
• Turbidimetry
Optical System-
• Principle: photometry
• Range of measurement: 0.0-3.0A
• Spectral range selection: Automatic via filter wheel
• Filters: 340, 405, 505, 546, 578 and 630 nm plus
two free position
• Bandwidth:10nm (+/- 2nm)
• Light source: Life Long Halogen lamp
• Blanking: Automatic
• Detector: Silicon Photodiode
Photometer-
• Peltier regulated 25ºC, 30ºC and 37ºC
• Flow cell of 18 µ L
• Continuous flow system with peristaltic pump
• Programmable Sipping Volume
Memory-
• 150+ User Defined Test Programs
• 1000 test results in instrument memory and unlimited test resultresult storage via cloud
• Reagent Blank
• 2 Level of QC
Quality Control-
• Levy-Jennings chart using westgard’s rules
• 30 Normal and abnormal QC values for selected test
User Interface-
• Graphic LCD back Lit 240×64 pixels
• Touch Screen input
• Data port and cloud connectivity
• Type : Graphic thermal printer
Power & Dimensions-
• Voltage : 220 V
• Frequency : 50 Hz
• Maximum power : < 150 VA
• Maximum relative humidity : 75%
• Compact form factor
• Weight: < 6kgs
Direction for Use
Please ensure that the power source is properly grounded and voltage between Line
and Ground is less than 2V AC – 5V AC.
• Please ensure that the instrument is placed on a firm table, clean environment, and
sufficient ventilation space.
• Switch On the instrument.
• Instrument will run its own internal diagnostic routines, to ensure proper working of
critical functions.
• Allow the instrument to stabilize for 10 minutes.
• During the stabilization time, please wash the flow cell with cleaning solution and
distilled water for at least two times.
• During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution
and rinsed thoroughly using distilled water.
• For overnight shutdown, please ensure flow cell is filled with distilled water.
• Cover the instrument with the given dust cover
Other Info
GENERAL INFORMATION
While installing and setting up the instrument, few safety warnings and general precautions
described in the further sections must be observed.
A. Power Supply :
• Power source should be grounded and have either servo stabilizer or regulated
power back up
• Power cord should be CE , CSA and UL marked
• Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz
• Grounding: Make sure that electrical power source is properly grounded.
Shamal Ranjit –
I have been using, Accurex SA machine from last one year, good product.
Uttam Walve –
I am using accurex instrument at112 highly quality and excellent accuracy.
Salim Hakim –
We are using accurex reagents and instruments. Very good product.
Rajesh Sinha –
Accurex Biomedical is excellent company,I am using it’s instruments and products. I am satisfied fully.
Sujit Bohar –
We are using Accurex Reagent and Instrument last 4years product is also good.