Renal Function Analysis Meter

Renal Function Analysis Meter

(1 customer review)

40,000.00

Overview

Buy The Renal Function Analysis Meter used for the quantitative determination of Uric Acid (UA), Creatinine (CR) and Urea (UR) in capillary blood, venous whole blood, plasma and serum. The easy to operate system consists of a portable meter that analyzes the intensity and color of light reflected from the reagent area of a Test strip, ensuring quick and accurate results. The

Renal Function Analyzer

can store up to 500 results and records. The meter can be operated by charging battery.

 

5 in stock

About

Renal Function Analysis Meter: RFM-101
Test strips: RFS-101,CRS-101,UAS-101,URS-101

The Renal Function Analysis Meter is intended for the quantitative determination
of Uric Acid (UA), Creatinine (CR) and Urea (UR) in capillary blood, venous whole blood, plasma and serum. The easy to operate system consists of a portable meter that analyzes the intensity and color of light reflected from the reagent area of a Test strip, ensuring quick and accurate results.
The Renal Function Analysis Meter provides results. The Renal Function Analysis Meter can store up to 500 results and records. The meter can be operated by charging battery.

Specification

The Blood Lipid Analysis System is intended for the quantitative determination of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL), Triglycerides (TG), and the calculated ratio of TC/HDL and Low Density Lipoprotein Cholesterol (LDL) in capillary blood, venous whole blood, plasma and serum. The Blood Lipid Analysis System provides results. The Blood Lipid meter can store up to 500 results and records. The meter can be operated by charging battery

Principle of measurement:
The analyzer applies the principle of photochemistry and is used with Renal Function test strips (RFS-101, UAS-101, CRS-101, URS-101) .The whole blood sample to be tested is added into the sample area of the strip. In the process of rapid infiltration, blood cells are filtered out or dissolved. The substrate reacts with enzymes and chemicals in the reaction layer and lead to the color change, then the color intensity is proportional to the concentration of the substance.

Safety Information

• Misuse of electrical meter can cause electrocution, burns, fire and other
hazards.
• Do not place the meter in liquid, nor put it where it could fall into liquid. If the meter becomes wet, unplug it before touching it.
• Use the meter only for the purpose described in the instructions for use.
• Failure to use the meter in the manner specified by the manufacturer may damage the protection provided by the meter.
• Do not use accessories which are not supplied or recommended by the manufacturer.
• Do not use the meter if it is not working properly or if it has suffered any damage.
• Do not let the meter come into contact with surfaces which are too hot to touch.
• Do not use the meter where aerosol sprays are being used or where oxygen is being administered.
• Do not use the meter out of doors.
• Control solution only purchased from local distributor or manufacturer
• Keep these instructions.
• For professional use.

Meter Use and Precautions
• Do not get water or other liquids on or inside the meter.
• Keep the Test Strip Holder clean.
• Keep the meter dry and avoid exposing it to extreme temperatures and humidity.
• Do not drop the meter or get it wet. If the meter is dropped or has gotten wet, ensure the meter is working properly by running an Optical Check. Refer to optical verify strips for details.
• Do not take the meter apart. Taking the meter apart will void the warranty.
• Refer to Maintenance for details on cleaning the meter.
• Keep the meter and all associated parts out of reach of children.

Caution: The adapter or computer should meet the requirements of current edition of the IEC60950-1. Lithium batteries meet the standard requirements of the IEC62133:2012

Direction for Use

For best results, the meter should be cleaned after each day of testing.
A cotton cloth can be used to clean the surface of the meter. Use a damp cotton cloth if necessary.
A dry, soft cloth may be used to clean the LCD and the sensor area. It is recommended that the meter be stored in the carrying case after each use.
Take care to avoid getting liquids, residue, or control solutions in the meter through the Test Strip Holder, Code Chip Slot or USB Port.
• If the control solution has been refrigerated, allow it to warm up to a temperature of 10 – 35°C before use.
• Each control solution will expire 3 months after the bottle is opened for the first time. Record this expiration date on the bottle label.

Other Info

• Store the control solution either refrigerated or at room temperature 2 – 30°C.
• Do not freeze.

1 review for Renal Function Analysis Meter

  1. Ahmed Tahir

    Chargeable device easy to use

Add a review

Your email address will not be published. Required fields are marked *

Fill Captcha *Time limit exceeded. Please complete the captcha once again.

×

Hello!

Click below to chat with us on WhatsApp

×