Renal Function Analysis Meter: RFM-101
Test strips: RFS-101,CRS-101,UAS-101,URS-101
The Renal Function Analysis Meter is intended for the quantitative determination
of Uric Acid (UA), Creatinine (CR) and Urea (UR) in capillary blood, venous whole blood, plasma and serum. The easy to operate system consists of a portable meter that analyzes the intensity and color of light reflected from the reagent area of a Test strip, ensuring quick and accurate results.
The Renal Function Analysis Meter provides results. The Renal Function Analysis Meter can store up to 500 results and records. The meter can be operated by charging battery.
Specification
The Blood Lipid Analysis System is intended for the quantitative determination of Total Cholesterol (TC), High Density Lipoprotein Cholesterol (HDL), Triglycerides (TG), and the calculated ratio of TC/HDL and Low Density Lipoprotein Cholesterol (LDL) in capillary blood, venous whole blood, plasma and serum. The Blood Lipid Analysis System provides results. The Blood Lipid meter can store up to 500 results and records. The meter can be operated by charging battery
Principle of measurement:
The analyzer applies the principle of photochemistry and is used with Renal Function test strips (RFS-101, UAS-101, CRS-101, URS-101) .The whole blood sample to be tested is added into the sample area of the strip. In the process of rapid infiltration, blood cells are filtered out or dissolved. The substrate reacts with enzymes and chemicals in the reaction layer and lead to the color change, then the color intensity is proportional to the concentration of the substance.
Direction for Use
For best results, the meter should be cleaned after each day of testing.
A cotton cloth can be used to clean the surface of the meter. Use a damp cotton cloth if necessary.
A dry, soft cloth may be used to clean the LCD and the sensor area. It is recommended that the meter be stored in the carrying case after each use.
Take care to avoid getting liquids, residue, or control solutions in the meter through the Test Strip Holder, Code Chip Slot or USB Port.
• If the control solution has been refrigerated, allow it to warm up to a temperature of 10 – 35°C before use.
• Each control solution will expire 3 months after the bottle is opened for the first time. Record this expiration date on the bottle label.
Other Info
• Store the control solution either refrigerated or at room temperature 2 – 30°C.
• Do not freeze.