HbA1c Direct 80 – Infinite (Without Calibrator)

HbA1c Direct 80 – Infinite (Without Calibrator)

(1 customer review)

40,731.00

Overview

Buy

Infinite HbA1c Direct 80 – Infinite (Without Calibrator) Diagnostic Reagent

(R1 1 X 15ml: R2: 1 X 5ml: R3 1 X 40ml) from Accurex. HbA1c Direct reagent kit is used for direct quantitative determination of Hemoglobin A1c (HbA1c) in whole blood.

HbA1c Direct 80 is ready-to-use, two liquid reagent system & is stable till expiry date indicated on the label when stored at 2°C-8°C. HbA1c normal range is below 5.7%, level of 5.7% to 6.4% indicates prediabetes & a level of 6.5% or more indicates diabetes.

5 in stock

About

  • Infinite HbA1c is a reagent kit for direct quantitative determination of Hemoglobin A1c (HbA1c) in whole blood
  • Infinite HbA1c is ready-to-use, two liquid reagent system
  • With Infinite HbA1c, the assay is linear up to 16% (NGSP
    Method – Latex Enhanced Immunoturbidimetric
    Pack Size : R1: 1 * 30 ml R2: 1 * 10 ml R3: 2 * 40 ml

Principle

Concentration in whole blood. Total hemoglobin & HbA1c have the same specific absorption rate to latex particles. When mouse anti human HoA 1c monoclonal antibody is added, latex-+IbA1c-mouse anti human HbA1c antibody complex is formed. Agglutination is formed when a goat anti-mouse IgG polyclonal antibody interacts with a monoclonal antibody. The amount of agglutination is proportional to the concentration of HA 1c in the specimen and is measured phototactically.

Procedure

Whenever the reagent lot is changed.
As per the requirement of quality control procedures.
Reaction Type……………End Point
Reaction direction…………… Increasing
Wavelength…………….650 nm
Flow Cell temperature…………… 37°C
Zero Setting with…………… Reagent Blank
Sample Volume…………… 10 pl
Reagent 1 (R1) volume………….. 360 pl
Reagent 2 (R2) volume……………120 pl
Linearity…………. 16%

Quality Control

To ensure adequate quality control, it is recommended that
each laboratory should use a normal and an abnormal
commercial reference control material. It should be realized
that the use of quality control material checks both reagent
and instrument functions together. Factors which might affect
the performance of this test include instrument function,
temperature control, cleanliness of glasswares and accuracy
of pipetting.

Other Details

Stable till expiry date indicated on the label when stored at 2°C -8°C

 

1 review for HbA1c Direct 80 – Infinite (Without Calibrator)

  1. Sonal Mitale

    innovative and indigenous products with good quality in house reagents…

Add a review

Your email address will not be published. Required fields are marked *

Fill Captcha *Time limit exceeded. Please complete the captcha once again.

×

Hello!

Click below to chat with us on WhatsApp

×