Calcium 200

Calcium 200

(2 customer reviews)

1,818.00

Overview

Buy

Autozyme Calcium 200 (CA) Diagnostic Reagent

from Accurex. Calcium reagent is used for determination of calcium based on colorimetric method using o-Cresol phthalein Complexioned.

Autozyme Calcium is a High Stability Reagent, can be determined in just 5 minutes. Blood Urea Nitrogen is a single reagent system using one step procedure. Calcium working solution is stable for 7 days at 2-8°C.Accurex has gained considerable expertise in manufacturing & marketing of In-vitro Diagnostic reagents.

50 in stock

About

  • Method – o-CPC
  • Need based, single step reconstitution
  • No interference from Mg and Fe
  • Autozyme Calcium is single reagent system for determination of calcium based on colorimetric method using o Cresolphthalein Complexone
  • Autozyme Calcium is linear up to 15 mg%
  • Autozyme Calcium is a High Stability Reagent
  • Autozyme Calcium has one step reconstitution. It involves mixing CPC and Diluent reagent
  • Calcium can be determined in 5 minutes
  • Autozyme Calcium has minimum reagent waste since working solution can be prepared according to the need
  • Interference of Mg and Fe is negligible. Lipemic samples do not require any specific treatment

Principle

Calcium forms a purple color complex with cresol phthalein complexone in alkaline medium. This complex absorbs light at 575 (570 – 580) nm. The intensity of the color is directly proportional to the calcium concentration in the specimen.

Procedure

Reaction type………………. End-Point
Reaction time………………….. 5 mins. at R.T. (25-30°C)
Wavelength…………………… 575 nm.(570 – 58 aim.)
Zero setting with ……………………… Reagent Blank
Sample volume……………………. 0.02 ml (20 11 1 )
Reagent volume…………………………….. 1.0 ml
Standard concentration ……………….10 mg%
Linearity…………………………… 15 mg/di

Quality Control

To ensure adequate quality control, it is recommended that each batch should include normal and an abnormal commercial reference control serum. It should be realized that the use of quality control material checks both instrument and reagent functions together. Factors which might affect the performance of this test include proper instrument function, temperature control, cleanliness of glassware and accuracy of Pipetting.

Other Details

  • The reagents are stable till the expiry date stated on the bottle label, when stored at 2-8°C.
  • The working solution is stable for 7 days at 2-8°C.

2 reviews for Calcium 200

  1. Jayesh Singh

    We are using accurex regents more than 8 parameters since 4 year’s the product quality is best

  2. Mannoj Yadav

    I’m fully satisfied with this reagent quality and services

Add a review

Your email address will not be published. Required fields are marked *

Fill Captcha *Time limit exceeded. Please complete the captcha once again.