CS – Diluent 20L for CBC-360 / CBC-360 Plus

CS – Diluent 20L for CBC-360 / CBC-360 Plus

(2 customer reviews)

6,365.00

Overview

Buy

Hematology Analyzer CS – Diluent 20L for CBC-360 / CBC-360 Plus

Online from Accurex. Diluents in Hematology Analyzers are solutions used before hematology testing to dilute blood samples in clinical settings.

Diluents may include solutions for use in blood cell counting & sizing & flow cytometry. Dilution makes haemocyte remain on original shape in the blood & safeguards in the dilution that the principal element of cell size shape has: Morie osmolarity, pH value, electric conductivity, cushioning effect power, ion what, ionic type, deformation force size, temperature.

50 in stock

About

In Hematology Analyzers, Blood cell analysis involves using hematololgy diluents. Diluents are used to dilute the whole-blood sample. The diluents allow portions of the diluted blood sample to be analyzed for red blood cells & platelets. Accurex Diluents can help determine hemoglobin, white blood cell count, and more.

Principle

The Diluent is a solution with certian ion strength and conductivity, which can dilute the blood and from the sheath flow, providing a stable enviornment for blood cell counting.
The diluent for the hematology analyzer comprises sodium chloride, sodium sulfate, a phosphate buffer agent, ethylene diamine tetraacetic acid, 1-pyridone-2-sulphur & formaldehyde & the pH value of the solution is 6.5-7.4, and preferably is 7.2; the content of each component is preferably as follows: 5g/L of sodium chloride, 10g/L of sodium sulfate, 0.3g/L of ethylene diamine tetraacetic acid, and 0.2ml/L of 1-pyridone-2-sulphur. The diluent for the hematology analyzer provided by the invention has the beneficial effects that general physical mixing can be adopted, and the preparation is extremely convenient.

Procedure

•Store in a dark place to avoid exposure to sunglight
•Avoid contact with skin and eyes. In case of contact, rinse immediately with water and seek medical advise. Avoid inhaling of evaportaed diluent.

Quality Control

•Ready to use
•Cap of the bottle should be tightly closed after every use
•Do not freeze
•Use reagent under professional guidance

Other Details

Manfucatured By:
Accurex Biomedical Pvt. Ltd

2 reviews for CS – Diluent 20L for CBC-360 / CBC-360 Plus

  1. Roshan Sharma

    All product are very good quality.

  2. Ramnivasan

    We are dealing Accurex reagent for last 10 yrs. Quality and service is good.

Add a review

Your email address will not be published. Required fields are marked *

Fill Captcha *Time limit exceeded. Please complete the captcha once again.