DRY BATH INCUBATOR
Specification
AT Smart Plus – India’s First Smart Biochemistry Analyzer
Redefining intelligence in biochemistry testing.
AT Smart Plus combines automation, connectivity, and intelligent data management—built for today’s modern diagnostic labs.
Key Highlights
- Automatic Programming
- 1000+ test programming slots
- Easy parameter downloads from cloud via Wi-Fi
- Supports up to 10 analytical methods (Endpoint, 2-Point Kinetic, Multi-Point Kinetic)
- Bi-chromatic and monochromatic readings
- Intelligent algorithms for automatic method detection (Spline, Linear, etc.)
- Built-in Peltier temperature control at 25 °C, 30 °C & 37 °C with in-built incubator
- Advanced Quality Control
- Supports both Control QC & Lab QC
- Multi-level QC (up to 30 normal and abnormal values)
- Levey-Jennings (LJ) plots with Mean, SD, 2SD & 3SD indicators
- Unlimited QC sample storage
- Result Management
- 1,00,000+ results stored internally
- Real-time reaction curve display for each test
- Patient details linked with every record
- Unlimited cloud-based data storage
- Smart User Interface
- 7” TFT colour capacitive touch screen
- HDMI output for external monitor
- Internal 57 mm thermal printer & USB external printer support
- 4 USB ports (for mouse, keyboard & printer), Ethernet port & HDMI port
- Automated Inventory Management
- Tracks reagent usage automatically
- Alerts for low stock levels
- Generates stock statements via email or printer
- Auto-entry for reagents in test programs downloaded from the cloud.
Direction for Use
Please ensure that the power source is properly grounded and voltage between Line
and Ground is less than 2V AC – 5V AC.
• Please ensure that the instrument is placed on a firm table, clean environment, and
sufficient ventilation space.
• Switch On the instrument.
• Instrument will run its own internal diagnostic routines, to ensure proper working of
critical functions.
• Allow the instrument to stabilize for 10 minutes.
• During the stabilization time, please wash the flow cell with cleaning solution and
distilled water for at least two times.
• During shut down, ensure that the flow cell is cleaned with flow cell cleaning solution
and rinsed thoroughly using distilled water.
• For overnight shutdown, please ensure flow cell is filled with distilled water.
• Cover the instrument with the given dust cover
Other Info
GENERAL INFORMATION
While installing and setting up the instrument, few safety warnings and general precautions
described in the further sections must be observed.
A. Power Supply :
• Power source should be grounded and have either servo stabilizer or regulated
power back up
• Power cord should be CE , CSA and UL marked
• Voltage : 115 – 230 Volts ± 10% 50 – 60 Hz
• Grounding: Make sure that electrical power source is properly grounded.